Main Technical Data
| Rated Voltage | 3.6kV-12kV |
| Frequency | 50Hz |
| Rated Current | 630A-3150A |
| Rated Short Time Withstand Current | 16kA-50kA (1s) |
| Rated Peak Withstand Current | 40kA-125kA |
Performance Features
Rational Structure
It features metal-clad and fully enclosed construction, with the low-voltage chamber and high-voltage chamber completely separated independently.
High Safety and Reliability
Busbars are insulated with heat-shrinkable materials to ensure superior insulation performance. Operations are only accessible when cabinet doors are fully closed, equipped with solid locking devices to effectively prevent mis-operation.
Strong Practicality
The cabinet reaches IP4X protection grade to block dust and small creatures. The maintenance-free handcart boasts fine interchangeability, enabling easy replacement of circuit breakers.
Convenient Observation
Front and rear observation windows allow direct viewing of breaker switching status, handcart position, mechanism energy storage and earthing switch state as well as cable terminal connections. Secondary wires are laid in spacious wire grooves for neat layout and easy inspection.
Wide Applicability
It supports cable inlet/outlet and overhead bus wiring modes, and allows connection of multiple parallel cables to meet diverse wiring demands.
Testing & Inspection
Scope of Application
Frequently Asked Questions
Q: What is the rated voltage range of this equipment?
The rated voltage ranges from 3.6kV to 12kV, making it suitable for indoor three-phase power systems with a frequency of 50/60Hz.
Q: What is the protection grade of the cabinet?
The cabinet reaches an IP4X protection grade, which effectively blocks dust and prevents small creatures from entering the enclosure.
Q: How does the design ensure operational safety?
It features a metal-clad, fully enclosed structure with completely separated low-voltage and high-voltage chambers. Additionally, operations are only accessible when the cabinet doors are fully closed and locked to prevent mis-operation.
Q: What tests are conducted to ensure product quality?
All products undergo rigorous testing according to standards and customer requirements, including partial discharge tests, lightning impulse withstand tests, noise level checks, and other key inspection items.
Q: Where is this equipment typically applied?
It is widely used in power plants, substations, industrial and mining enterprises, and high-rise buildings to receive and distribute electrical energy while providing control, protection, and monitoring.