China Suppliers YT2-H Series Three-Phase Marine Induction Motor Factory for Axial Flow Fan Ventilation Systems
Main Technical Data
| Frame Size | 63~355 | Protection Class | IP44~IP56 |
| Power | 0.12~315kW | Insulation Class | B or F |
| Voltage | 380V or 440V | Ambient Temperature | 0℃~45℃ |
| Frequency | 50Hz or 60Hz | Altitude | 0m |
Testing & Inspection
All motors are subject to rigorous standard electrical performance tests including winding resistance, temperature rise, efficiency and withstand voltage, as well as marine-specific tests required by IEC 60092 and classification society rules, such as tilt & rolling test, long-term salt spray corrosion test, damp heat alternating cycle test, mould-resistance test, voltage fluctuation endurance and mechanical shock test. Besides, marine motors adopt stricter limits on vibration, noise and IP protection, and pass full flame-retardant inspection for cabin safety before class certification.
Scope of Application
This series of Three-Phase Marine Induction Motors for Axial Flow Fans is professionally engineered to match the operation needs of marine ventilation systems. Besides driving all types of axial flow fans for cabin ventilation and exhaust, they can also reliably power supporting shipboard equipment including water pumps, air blowers, oil-water separators and hydraulic units, as well as a full set of standard auxiliary machinery stably installed on various vessels under salty, humid marine environments.
Frequently Asked Questions
What is the protection class range of these marine motors?
The protection class of these marine induction motors ranges from IP44 to IP56, ensuring high resistance to water and dust penetration in harsh environments.
What specific marine tests do these motors undergo?
They undergo rigorous marine-specific tests required by IEC 60092 and classification societies, including tilt & rolling, long-term salt spray corrosion, damp heat alternating cycle, mould-resistance, and mechanical shock tests.
Can these motors be used for equipment other than axial flow fans?
Yes. While designed for marine axial flow fans, they are also suitable for driving water pumps, air blowers, oil-water separators, hydraulic units, and other standard shipboard auxiliary machinery.
What are the power and voltage specifications available?
These motors offer a power range of 0.12 to 315kW and support voltages of 380V or 440V at frequencies of either 50Hz or 60Hz.
How do these motors ensure safety inside ship cabins?
They adopt strict design limits on vibration and noise, feature enhanced IP protection, and must pass a full flame-retardant inspection to guarantee cabin safety before receiving class certification.